Split/Splitless Injector SL/IN

Split/Splitless Injector - SL/IN

The most popular GC injector features an outstanding design and thanks to the patented DFC provides excellent precision in split, splitless, and pulsed injection modes of operation. In addition, the post-injection carrier gas save mode is a valuable cost-saving feature. To fulfill the user’s analytical needs a series of liner types are available, including liners suitable for SPME analysis.

Split Injection

Split injection is one of the simplest and easiest injection technique to use. The procedure involves injection about 1 μL of liquid sample by a standard 10 μl syringe into a heated injection port. The sample is rapidly vaporized, and only a fraction, usually 1-2%, of the vapor enters the column. The rest of the vaporized sample and a large flow of carrier gas passes out through a “split” valve.

There are several advantages of split injections. The technique is simple, because the operator has only to control the split ratio by opening or closing the split valve. The sample amount introduced to the column is very small (and easily controlled), and the flow rate up to the split point is fast (the sum of both column and vent flow rates). The result is high resolution separations. Another advantage is that “neat” samples can also be introduced, usually by using a larger split ratio, so there is no need to dilute the sample. A final advantage is that “dirty” samples can be introduced by putting a plug of deactivated glass wool in the inlet liner to trap nonvolatile compounds.

One disadvantage is that trace analysis is somewhat limited since only a fraction of the sample enters the column. Consequently, splitless, or PTV techniques are recommended for trace analysis.

Splitless Injection

Splitless injection uses the same hardware as split injection (Figure 10), but the split valve is initially closed. The sample is diluted in a volatile solvent (like hexane or methanol) and injected in the heated injection port. The sample is vaporized and slowly (flow rate of about 1 mL/min) carried onto a cold column where both sample and solvent are condensed. After about 45-60 seconds, the split valve is opened (flow rate of about 50 mL/min), and any residual vapors left in the injection port are rapidly swept out of the system. Septum purge of 2-3 ml/min is essential with splitless injections. In optimal conditions, relatively high sample volumes can be injected to achieve the sensitivity required by the analysis of traces.

In an electronically controlled inlet, a “pulsed pressure” mode can be used to improve the sample transfer in splitless injection: the column head pressure increases immediately upon injection, for example to 80 or 100 psi to reduce the sample vapor volume (PV = nRT). After one minute, when all sample vapors are in the column the inlet pressure is reduced back to normal operating pressure (for example 20-30 psi).

The column is now temperature programmed, and initially only the volatile solvent is vaporized and carried through the column. While this is happening, the sample analytes are being refocused into a narrow band at the head of the column. At some later time, these analytes are vaporized by the hotter column and pass through the system. High resolution of these higher boiling analytes is now observed.

The big advantage of splitless injection is the improved sensitivity over split. Typically 20- to 50-fold more sample enters the column and the result is improved trace analysis for environmental, pharmaceutical, or biomedical samples.

Splitless has several disadvantages, however; it is time-consuming; you must start with a cold column, and you must temperature program. You must also dilute the sample with a volatile solvent, and optimize both the initial column temperature and the time of opening the split valve. Finally, splitless injection is not well-suited for volatile and thermally labile compounds.

GC Injectors


SL/IN

Split/Splitless Injector

PTV

Programmable Temperature Vaporizer

PK

Packed Injector

GC Detectors


FID

Flame Ionization Detector

NPD

Nitrogen-Phosphorus Detector

TCD

Thermal Conductivity Detector

FPD

Flame Photometric Detector

ECD

Electron Capture Detector

TOF-MS Plus

Time of Flight

DANI Instruments Portfolio


Master GC

Fast GC Gas Chromatograph
A Breakthrough in Fast GC Performance

Master GC TURN-KEY ANALYZERS

Turn-Key Analyzers
Superior Petrochemical Solutions

Master TOF MS PLUS

Time of Flight
Speed is Knowledge

PeakBlade 77

GCxGC Modulator
Unfold Complexity

DiscovIR GC

GC-IR Detection System
A Beam of 
Confidence

Master AS

Automatic Liquid Autosampler
High Sample Throughput Liquid Autosampler

Master SHS

Static Headspace Sampler
Outstanding Sensitivity

HSS 86.50 Plus

Static Headspace Sampler
Affordable Excellence

Master DHS

Dynamic Headspace Sampler
Ultimate Versatility

Master P&T

Purge&Trap Sampler
Compliant Innovation

Master TD

Thermal Desorber
Extended Sampling, Outstanding Sensitivity

Share This